-- TN-ETHSOAM-PM-MIB.my : TN Ethernet OAM MIB
--
-- Author : Angela Xing & Tony Lei
--
-- Copyright (c) 2009 by Transition Networks, Inc.
-- All rights reserved.
--
-- *************************************************************************************************
--

TN-ETHSOAM-PM-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter64, Unsigned32
        FROM SNMPv2-SMI
    DateAndTime, TimeInterval, RowStatus
        FROM SNMPv2-TC
    tnEthSoaminstance
        FROM TN-ETHSOAM-MIB
    tnEvcIndex, tnEvcEceId
        FROM TN-EVC-MIB
    ifIndex
        FROM IF-MIB
    tnProducts
        FROM TRANSITION-SMI;


--
-- main body
--
tnEthSoamPmMIB MODULE-IDENTITY
    LAST-UPDATED    "201403281200Z"
    ORGANIZATION    "Transition Networks, Inc."
    CONTACT-INFO
            "Transition Networks
             Technical Support
             10900 Red Circle Drive
             Minnetonka, MN 55343 USA
             Tel: +1-800-526-9267
             E-mail: techsupport@transition.com
            "
    DESCRIPTION
           "This MIB module contains the Performance Monitoring objects for
            the management of Ethernet Services Operations, Administration
            and Maintenance in TN platform products."
    REVISION        "201403281200Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { tnProducts 143 }


-- 1.3.6.1.4.1.868.2.5.143.0
tnEthSoamPmNotifications           OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 0 }
-- 1.3.6.1.4.1.868.2.5.143.1
tnEthSoamPmCfgMIBObjects           OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 1 }
-- 1.3.6.1.4.1.868.2.5.143.2
tnEthSoamPmStatsMIBObjects         OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 2 }
-- 1.3.6.1.4.1.868.2.5.143.3
tnEthSoamPmNotificationMIBObjects  OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 3 }

--
-- sub Objects list
--
tnEthSoamPmSessionCfgObjects       OBJECT IDENTIFIER ::= { tnEthSoamPmCfgMIBObjects 1 }
tnEthSoamPmTransferCfgObjects      OBJECT IDENTIFIER ::= { tnEthSoamPmCfgMIBObjects 2 }
-- tnEthSoamPmThresholdCfgObjects     OBJECT IDENTIFIER ::= { tnEthSoamPmCfgMIBObjects 3 }

tnEthSoamPmLmStatsObjects          OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 1 }
tnEthSoamPmDmStatsObjects          OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 2 }
tnEthSoamPmEvcStatsObjects         OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 3 }
tnEthSoamPmEceStatsObjects         OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 4 }
-- tnEthSoamPmPortStatsObjects        OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 5 }
-- tnEthSoamPmThresholdStatsObjects   OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 6 }

-- 1.3.6.1.4.1.868.2.5.143.3.1
-- tnEthSoamPmThresholdCrossingNotifObj OBJECT IDENTIFIER ::= { tnEthSoamPmNotificationMIBObjects 1 }


-- ******************************************************************
-- TN Ethernet Performance Measurement Session Configuration Table
-- ******************************************************************
tnEthSoamPmSessionCfgTable OBJECT-TYPE
    SYNTAX SEQUENCE OF TnEthSoamPmSessionCfgEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "This table configure the Performance monitor session and storage settings.
        "
    ::= { tnEthSoamPmSessionCfgObjects 1 }

tnEthSoamPmSessionCfgEntry OBJECT-TYPE
    SYNTAX TnEthSoamPmSessionCfgEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "Entries in this table configure the Performance monitor session and storage settings.
        "
    INDEX { tnEthSoamPmSessionCfgId }
    ::= { tnEthSoamPmSessionCfgTable 1 }

TnEthSoamPmSessionCfgEntry ::=
    SEQUENCE {
        tnEthSoamPmSessionCfgId            Integer32,
        tnEthSoamPmSessionCfgType          INTEGER,
        tnEthSoamPmSessionCfgSessionMode   INTEGER,
        tnEthSoamPmSessionCfgStorageMode   INTEGER,
        tnEthSoamPmSessionCfgInterval      Unsigned32
     }

tnEthSoamPmSessionCfgId OBJECT-TYPE
    SYNTAX Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "An index to the Performce Monitor Configuration table which indicates
        the specific session to be configured.
        "
    ::= { tnEthSoamPmSessionCfgEntry 1 }

tnEthSoamPmSessionCfgType OBJECT-TYPE
    SYNTAX INTEGER {
        lossMeasurement(1),
        delayMeasurement(2),
        evc(3),
        ece(4),
        dmBinning(5)
    }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The Perfmonce Monitor session type:
          - lossMeasurement   SOAM PM loss measurement collect and storage.
          - delayMeasurement  SOAM PM delay measurement collect and storage.
          - evc               EVC Port based counters collect and storage.
          - ece               ECE Port based counters collect and storage.
          - port              Port based counters collect and storage.
        "
    ::= { tnEthSoamPmSessionCfgEntry 2 }

tnEthSoamPmSessionCfgSessionMode OBJECT-TYPE
    SYNTAX INTEGER {
        enabled(1),
        disabled(2)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "Enable or disable this performance monitor session.
        "
    ::= { tnEthSoamPmSessionCfgEntry 3 }

tnEthSoamPmSessionCfgStorageMode OBJECT-TYPE
    SYNTAX INTEGER {
        enabled(1),
        disabled(2)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "Enable or disable the performance monitor local storage.
        "
    ::= { tnEthSoamPmSessionCfgEntry 4 }

tnEthSoamPmSessionCfgInterval OBJECT-TYPE
    SYNTAX Unsigned32
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "The measurement interval for the performance monitor.
         The interval unit is minute, the valid range is system defined.
         A typical range would be 1 - 60(mins)
        "
    ::= { tnEthSoamPmSessionCfgEntry 5 }


-- ******************************************************************
-- TN Ethernet Performance Measurement Transfer Configuration Table
-- ******************************************************************
tnEthSoamPmTransferCfgTable OBJECT-TYPE
    SYNTAX SEQUENCE OF TnEthSoamPmTransferCfgEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "This table configure the Performance Monitor data transfer related settings.
        "
    ::= { tnEthSoamPmTransferCfgObjects 1 }


tnEthSoamPmTransferCfgEntry OBJECT-TYPE
    SYNTAX TnEthSoamPmTransferCfgEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "Entry in this table configure the Performance Monitor data transfer related settings.
        "
    INDEX { tnEthSoamPmTransferCfgId }
    ::= { tnEthSoamPmTransferCfgTable 1 }

TnEthSoamPmTransferCfgEntry ::=
    SEQUENCE {
        tnEthSoamPmTransferCfgId                     Integer32,
        tnEthSoamPmTransferCfgMode                   INTEGER,
        tnEthSoamPmTransferCfgSchedHrs               BITS,
        tnEthSoamPmTransferCfgSchedMins              BITS,
        tnEthSoamPmTransferCfgSchedOffset            Integer32,
        tnEthSoamPmTransferCfgRandomOffset           Integer32,
        tnEthSoamPmTransferCfgServerAddr             OCTET STRING,
        tnEthSoamPmTransferCfgIntervalMode           INTEGER,
        tnEthSoamPmTransferCfgIntervalNum            Integer32,
        tnEthSoamPmTransferCfgIncludeIncomplete      INTEGER
     }

tnEthSoamPmTransferCfgId OBJECT-TYPE
    SYNTAX Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "Indicate the performance monitor data transfer table index.
        "
    ::= { tnEthSoamPmTransferCfgEntry 1 }

tnEthSoamPmTransferCfgMode OBJECT-TYPE
    SYNTAX INTEGER {
        enabled(1),
        disabled(2)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "Configure the performance monitor transfer mode per system. Possible modes are:
         - Enabled:  Transfer data is enabled.
         - Disabled: Transfer data is disabled.
        "
    ::= { tnEthSoamPmTransferCfgEntry 2 }

tnEthSoamPmTransferCfgSchedHrs OBJECT-TYPE
    SYNTAX BITS {
                hrs00(0),
                hrs01(1),
                hrs02(2),
                hrs03(3),
                hrs04(4),
                hrs05(5),
                hrs06(6),
                hrs07(7),
                hrs08(8),
                hrs09(9),
                hrs10(10),
                hrs11(11),
                hrs12(12),
                hrs13(13),
                hrs14(14),
                hrs15(15),
                hrs16(16),
                hrs17(17),
                hrs18(18),
                hrs19(19),
                hrs20(20),
                hrs21(21),
                hrs22(22),
                hrs23(23)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "It must be possible to select one or more of the 24 hours in a day, when PM data transfer will happen.
                00:00
                01:00
                02:00
                03:00
                04:00
                05:00
                06:00
                07:00
                08:00
                09:00
                10:00
                11:00
                12:00
                13:00
                14:00
                15:00
                16:00
                17:00
                18:00
                19:00
                20:00
                21:00
                22:00
                23:00
         Default is none selected.
        "
    ::= { tnEthSoamPmTransferCfgEntry 3 }

tnEthSoamPmTransferCfgSchedMins OBJECT-TYPE
    SYNTAX BITS {
        mins00(0),
        mins15(1),
        mins30(2),
        mins45(3)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "It must be possible to select one or more of the four 15 min. in an hour, when PM data transfer will happen.
                00:00
                00:15
                00:30
                00:45
         Default is none selected.
        "
    ::= { tnEthSoamPmTransferCfgEntry 4 }

tnEthSoamPmTransferCfgSchedOffset OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "It must be possible to configure a fixed offset that is added to the scheduled transfer time.
         The rage is 0-15 minutes. Default is 0 min.
         The sum of Scheduled Fixed Offset and Scheduled Random Offset must not exceed 15 min.
        "
    ::= { tnEthSoamPmTransferCfgEntry 5 }

tnEthSoamPmTransferCfgRandomOffset OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "It must be possible to configure a random offset that is added to the scheduled transfer time.
         The offset added to the scheduled transfer time must be a random value in the range 0-Scheduled Offset.
         The range is 0-900 seconds. Default is 0 sec.
         The sum of Scheduled Offset and Random Offset must not exceed 15 min.
        "
    ::= { tnEthSoamPmTransferCfgEntry 6 }

tnEthSoamPmTransferCfgServerAddr OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (0..63))
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "It must be possible to configure the full URL of the server and the
         corresponding directory (if any) for uploading.
         The supported protocols are HTTP and TFTP.
         To enable HTTP by entering http:// followed by the domain name or IP address.
         To enable TFTP by entering tftp:// followed by the domain name or IP address.
         The format is:
             protocol://host_address:port_num/folder_name
         while port_num and folder_name are optional.
         For example, 'tftp://192.251.1.1:55/' will upload the counter files to
         the tftp root directory in 192.251.1.1 at port 55 via tftp.
        "
    ::= { tnEthSoamPmTransferCfgEntry 7 }

tnEthSoamPmTransferCfgIntervalMode OBJECT-TYPE
    SYNTAX INTEGER {
        allAvailableIntervals(1),
        newIntervalsSinceLastTransfer(2),
        fixedNumberOfIntervals(3)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "There are three supported interval modes.
         All available intervals: To enable transfer of all completed Measurement Intervals.
         New intervals since last transfer: To enable transfer of only completed Measurement Intervals since last transfer.
         Fixed number of intervals: To enable transfer of all completed Measurement Intervals up to the configured number. 
        "
    ::= { tnEthSoamPmTransferCfgEntry 8 }

tnEthSoamPmTransferCfgIntervalNum OBJECT-TYPE
    SYNTAX Integer32 (1..96)
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        " When Fixed number of interval selected, this value is used to determine the number of intervals to send.
          The range is 1 to 96 Intervals.
        "
    ::= { tnEthSoamPmTransferCfgEntry 9 }

tnEthSoamPmTransferCfgIncludeIncomplete OBJECT-TYPE
    SYNTAX INTEGER {
        enabled(1),
        disabled(2)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "When this option is checked, PM data transfer will include the suspended (incomplete) transmission.
         - Enabled:  PM data transfer will include the suspended (incomplete) transmission.
         - Disabled: PM data transfer will not include the suspended (incomplete) transmission.
        "
    ::= { tnEthSoamPmTransferCfgEntry 10 }

-- ******************************************************************
-- TN Ethernet Loss Measurement History Statistic Table
-- ******************************************************************
tnEthSoamPmLmHistoryStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TnEthSoamPmLmHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "This table contains the results for availability history Measurement
        Intervals in a SOAM Loss Measurement session.

        Rows of this table object are created automatically
        by the SNMP Agent when the Loss Measurement session is running and a
        Measurement Interval is completed.

        Each row in the table represents the history statistics for a Loss
        Measurement session availability Measurement Interval for the defined
        MEP.

        32 completed Measurement Intervals are to be supported. If
        there are at least 32 rows in the table and a new Measurement Interval
        completes and a new row is to be added to the table, the oldest completed
        Measurement Interval is deleted (row deletion).

        The rows and objects in this table are to be persistent upon reboot
        or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
        for tnEthSoamPmSessionCfgType of 'lossMeasurement'.
       "
    ::= { tnEthSoamPmLmStatsObjects 1 }

tnEthSoamPmLmHistoryStatsEntry OBJECT-TYPE
    SYNTAX      TnEthSoamPmLmHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "The conceptual row of tnEthSoamPmLmHistoryStatsTable"
    INDEX      { tnEthSoamPmLmHistoryStatsIndex, tnEthSoaminstance }
    ::= { tnEthSoamPmLmHistoryStatsTable 1 }

TnEthSoamPmLmHistoryStatsEntry ::= SEQUENCE {
    tnEthSoamPmLmHistoryStatsIndex                     Unsigned32,
    tnEthSoamPmLmHistoryStatsEndTime                   DateAndTime,
    tnEthSoamPmLmHistoryStatsElapsedTime               TimeInterval,
    tnEthSoamPmLmHistoryStatsTxCount                   Counter64,
    tnEthSoamPmLmHistoryStatsRxCount                   Counter64,
    tnEthSoamPmLmHistoryStatsNELossCount               Counter64,
    tnEthSoamPmLmHistoryStatsFELossCount               Counter64,
    tnEthSoamPmLmHistoryStatsNEAvgFlr                  Unsigned32,
    tnEthSoamPmLmHistoryStatsFEAvgFlr                  Unsigned32
}

tnEthSoamPmLmHistoryStatsIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "The index for the Measurement Interval within this PM session.

        Measurement Interval indexes are assigned sequentially by
        the device.  The first Measurement Interval that occurs after
        the session is started is assigned index 1.

        Referential integrity is necessary, i.e., the index needs to be
        persistent upon a reboot or restart of a device.  The index
        is never reused while this session is active until it wraps to zero.
        The index value keeps increasing up to that time.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 1 }

tnEthSoamPmLmHistoryStatsEndTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval ended.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 2 }

tnEthSoamPmLmHistoryStatsElapsedTime OBJECT-TYPE
    SYNTAX      TimeInterval
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval has been running, in 0.01
        seconds.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 3 }

tnEthSoamPmLmHistoryStatsTxCount OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound frames
        in this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 4 }

tnEthSoamPmLmHistoryStatsRxCount OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames
        in this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 5 }

tnEthSoamPmLmHistoryStatsNELossCount OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of frames lossed in the
        near end of this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 6 }

tnEthSoamPmLmHistoryStatsFELossCount OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of frames lossed in the
        far end of this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 7 }

tnEthSoamPmLmHistoryStatsNEAvgFlr       OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000)
    UNITS       "milli-percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average frame loss ratio in the
        near end of this MEP calculated for this Measurement Interval.
        The value is a ratio that is expressed as a
        percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00).

        Units are in milli-percent, where 1 indicates 0.001 percent.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 8 }

tnEthSoamPmLmHistoryStatsFEAvgFlr       OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000)
    UNITS       "milli-percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average frame loss ratio in the
        far end of this MEP calculated for this Measurement Interval.
        The value is a ratio that is expressed as a
        percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00).

        Units are in milli-percent, where 1 indicates 0.001 percent.
       "
    ::= { tnEthSoamPmLmHistoryStatsEntry 9 }


-- ******************************************************************
-- TN Ethernet Delay Measurement History Statistic Table
-- ******************************************************************
tnEthSoamPmDmHistoryStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TnEthSoamPmDmHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "This table contains the results for history Measurement
        Intervals in a SOAM Delay Measurement session.

        Rows of this table are created automatically
        by the SNMP Agent when the Delay Measurement session is running and a
        Measurement Interval is completed.

        Each row in the table represents the Measurement Interval history
        statistics for a Delay Measurement session for the defined MEP.


        Each row in the table represents the history statistics for a delay 
        Measurement session availability Measurement Interval for the defined
        MEP.

        32 completed Measurement Intervals are to be supported. If
        there are at least 32 rows in the table and a new Measurement Interval
        completes and a new row is to be added to the table, the oldest completed
        Measurement Interval is deleted (row deletion).

        The rows and objects in this table are to be persistent upon reboot
        or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
        for tnEthSoamPmSessionCfgType of 'delayMeasurement'.
       "
    ::= { tnEthSoamPmDmStatsObjects 1 }

tnEthSoamPmDmHistoryStatsEntry OBJECT-TYPE
    SYNTAX      TnEthSoamPmDmHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "The conceptual row of tnEthSoamPmDmHistoryStatsTable"
    INDEX      { tnEthSoamPmDmHistoryStatsIndex, tnEthSoaminstance }
    ::= { tnEthSoamPmDmHistoryStatsTable 1 }

TnEthSoamPmDmHistoryStatsEntry ::= SEQUENCE {
    tnEthSoamPmDmHistoryStatsIndex                 Unsigned32,
    tnEthSoamPmDmHistoryStatsEndTime               DateAndTime,
    tnEthSoamPmDmHistoryStatsElapsedTime           TimeInterval,
    tnEthSoamPmDmHistoryStatsTxCount               Counter64,
    tnEthSoamPmDmHistoryStatsRxCount               Counter64,
    tnEthSoamPmDmHistoryStatsFNAvgFrameDelay       Unsigned32,
    tnEthSoamPmDmHistoryStatsFNAvgFrameDV          Unsigned32,
    tnEthSoamPmDmHistoryStatsFNMinFrameDelay       Unsigned32,
    tnEthSoamPmDmHistoryStatsFNMaxFrameDelay       Unsigned32,
    tnEthSoamPmDmHistoryStatsNFAvgFrameDelay       Unsigned32,
    tnEthSoamPmDmHistoryStatsNFAvgFrameDV          Unsigned32,
    tnEthSoamPmDmHistoryStatsNFMinFrameDelay       Unsigned32,
    tnEthSoamPmDmHistoryStatsNFMaxFrameDelay       Unsigned32,
    tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDelay   Unsigned32,
    tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDV      Unsigned32,
    tnEthSoamPmDmHistoryStatsTwoWayMinFrameDelay   Unsigned32,
    tnEthSoamPmDmHistoryStatsTwoWayMaxFrameDelay   Unsigned32
}

tnEthSoamPmDmHistoryStatsIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "The index for the Measurement Interval within this PM session.

        Measurement Interval indexes are assigned sequentially by
        the device.  The first Measurement Interval that occurs after
        the session is started is assigned index 1.

        Referential integrity is necessary, i.e., the index needs to be
        persistent upon a reboot or restart of a device.  The index
        is never reused while this session is active until it wraps to zero.
        The index value keeps increasing up to that time.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 1 }

tnEthSoamPmDmHistoryStatsEndTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval ended.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 2 }

tnEthSoamPmDmHistoryStatsElapsedTime OBJECT-TYPE
    SYNTAX      TimeInterval
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval has been running, in 0.01
        seconds.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 3 }

tnEthSoamPmDmHistoryStatsTxCount OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of frames transmitted
        in this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 4 }

tnEthSoamPmDmHistoryStatsRxCount OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of frames received 
        in this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 5 }

tnEthSoamPmDmHistoryStatsFNAvgFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average one-way frame delay
        in the far end to near end direction calculated by this MEP
        for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 6 }

tnEthSoamPmDmHistoryStatsFNAvgFrameDV OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average one-way inter-frame delay
        interval in the far end to near end direction calculated by
        this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 7 }

tnEthSoamPmDmHistoryStatsFNMinFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the minimum one-way inter-frame delay
        interval in the far end to near end direction calculated by
        this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 8 }

tnEthSoamPmDmHistoryStatsFNMaxFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the maximum one-way inter-frame delay
        interval in the far end to near end direction calculated by
        this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 9 }

tnEthSoamPmDmHistoryStatsNFAvgFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average one-way frame delay
        in the near end to far end direction calculated by this MEP
        for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 10 }

tnEthSoamPmDmHistoryStatsNFAvgFrameDV OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average one-way inter-frame delay
        interval in the near end to far end direction calculated by
        this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 11 }

tnEthSoamPmDmHistoryStatsNFMinFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the minimum one-way inter-frame delay
        interval in the near end to far end direction calculated by
        this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 12 }

tnEthSoamPmDmHistoryStatsNFMaxFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the maximum one-way inter-frame delay
        interval in the near end to far end direction calculated by
        this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 13 }

tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average two-way inter-frame delay
        interval direction calculated by this MEP for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 14 }

tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDV OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the average two-way inter-frame delay
        interval calculated by this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 15 }

tnEthSoamPmDmHistoryStatsTwoWayMinFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the minimum two-way inter-frame delay
        interval calculated by this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 16 }

tnEthSoamPmDmHistoryStatsTwoWayMaxFrameDelay OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the maximum two-way inter-frame delay
        interval calculated by this MEP for this Measurement Interval.
       "
    ::= { tnEthSoamPmDmHistoryStatsEntry 17 }


-- ******************************************************************
-- TN Ethernet EVC History Statistic Table
-- ******************************************************************
tnEthSoamPmEvcHistoryStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TnEthSoamPmEvcHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "This table contains the results for history Measurement
        Intervals in a SOAM EVC Measurement session.

        Rows of this table object are created automatically
        by the SNMP Agent when the EVC Measurement session is running and a
        Measurement Interval is completed.

        Each row in the table represents the history statistics for a EVC 
        Measurement session availability Measurement Interval for the defined
        EVC.

        32 completed Measurement Intervals are to be supported. If
        there are at least 32 rows in the table and a new Measurement Interval
        completes and a new row is to be added to the table, the oldest completed
        Measurement Interval is deleted (row deletion).

        The rows and objects in this table are to be persistent upon reboot
        or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
        for tnEthSoamPmSessionCfgType of 'evc'.
       "
    ::= { tnEthSoamPmEvcStatsObjects 1 }

tnEthSoamPmEvcHistoryStatsEntry OBJECT-TYPE
    SYNTAX      TnEthSoamPmEvcHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "The conceptual row of tnEthSoamPmEvcHistoryStatsTable"
    INDEX      { tnEthSoamPmEvcHistoryStatsIndex, tnEvcIndex, ifIndex }
    ::= { tnEthSoamPmEvcHistoryStatsTable 1 }

TnEthSoamPmEvcHistoryStatsEntry ::= SEQUENCE {
    tnEthSoamPmEvcHistoryStatsIndex                  Unsigned32,
    tnEthSoamPmEvcHistoryStatsEndTime                DateAndTime,
    tnEthSoamPmEvcHistoryStatsElapsedTime            TimeInterval,
    tnEthSoamPmEvcHistoryStatsGreenFramesTx          Counter64,
    tnEthSoamPmEvcHistoryStatsGreenFramesRx          Counter64,
    tnEthSoamPmEvcHistoryStatsGreenBytesTx           Counter64,
    tnEthSoamPmEvcHistoryStatsGreenBytesRx           Counter64,
    tnEthSoamPmEvcHistoryStatsYellowFramesTx         Counter64,
    tnEthSoamPmEvcHistoryStatsYellowFramesRx         Counter64,
    tnEthSoamPmEvcHistoryStatsYellowBytesTx          Counter64,
    tnEthSoamPmEvcHistoryStatsYellowBytesRx          Counter64,
    tnEthSoamPmEvcHistoryStatsRedFramesRx            Counter64,
    tnEthSoamPmEvcHistoryStatsRedBytesRx             Counter64,
    tnEthSoamPmEvcHistoryStatsDiscardFramesTx        Counter64,
    tnEthSoamPmEvcHistoryStatsDiscardFramesRx        Counter64,
    tnEthSoamPmEvcHistoryStatsDiscardBytesTx         Counter64,
    tnEthSoamPmEvcHistoryStatsDiscardBytesRx         Counter64
}

tnEthSoamPmEvcHistoryStatsIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "The index for the Measurement Interval within this PM session.

        Measurement Interval indexes are assigned sequentially by
        the device.  The first Measurement Interval that occurs after
        the session is started is assigned index 1.

        Referential integrity is necessary, i.e., the index needs to be
        persistent upon a reboot or restart of a device.  The index
        is never reused while this session is active until it wraps to zero.
        The index value keeps increasing up to that time.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 1 }

tnEthSoamPmEvcHistoryStatsEndTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval ended.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 2 }

tnEthSoamPmEvcHistoryStatsElapsedTime OBJECT-TYPE
    SYNTAX      TimeInterval
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval has been running, in 0.01
        seconds.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 3 }

tnEthSoamPmEvcHistoryStatsGreenFramesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound frames within 
        the CIR / CBS compliance level in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 4 }

tnEthSoamPmEvcHistoryStatsGreenFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames within 
        the CIR / CBS compliance level in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 5 }

tnEthSoamPmEvcHistoryStatsGreenBytesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound bytes, where
        frames are within the CIR / CBS compliance level in this
        EVC for this Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 6 }

tnEthSoamPmEvcHistoryStatsGreenBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes, where
        frames are within the CIR / CBS compliance level in this
        EVC for this Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 7 }

tnEthSoamPmEvcHistoryStatsYellowFramesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound frames exceeding
        the CIR/CBS but within the EIR/EBS in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 8 }

tnEthSoamPmEvcHistoryStatsYellowFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames exceeding
        the CIR/CBS but within the EIR/EBS in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 9 }

tnEthSoamPmEvcHistoryStatsYellowBytesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound bytes, where
        frames exceed the CIR/CBS but are within the EIR/EBS
        in this EVC for this Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 10 }

tnEthSoamPmEvcHistoryStatsYellowBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes, where
        frames exceed the CIR/CBS but are within the EIR/EBS
        in this EVC for this Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 11 }

tnEthSoamPmEvcHistoryStatsRedFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames
        not conforming to either the CIR/CBS or the EIR/EBS
        in this EVC for this Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 12 }

tnEthSoamPmEvcHistoryStatsRedBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes, where
        frames do not conform to either the CIR/CBS or the EIR/EBS
        in this EVC for this Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 13 }

tnEthSoamPmEvcHistoryStatsDiscardFramesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound frames which
        were chosen to be discarded in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 14 }

tnEthSoamPmEvcHistoryStatsDiscardFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames which
        were chosen to be discarded in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 15 }

tnEthSoamPmEvcHistoryStatsDiscardBytesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound bytes which
        were chosen to be discarded in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 16 }

tnEthSoamPmEvcHistoryStatsDiscardBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes which
        were chosen to be discarded in this EVC for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEvcHistoryStatsEntry 17 }


-- ******************************************************************
-- TN Ethernet ECE History Statistic Table
-- ******************************************************************
tnEthSoamPmEceHistoryStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TnEthSoamPmEceHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "This table contains the results for history Measurement
        Intervals in a SOAM EVC Extention (ECE) Measurement session.
        It provides port statistics for the UNI ports of EVC.

        Rows of this table object are created automatically
        by the SNMP Agent when the ECE Measurement session is running and a
        Measurement Interval is completed.

        Each row in the table represents the history statistics for a ECE
        Measurement session availability Measurement Interval for the defined
        ECE.

        32 completed Measurement Intervals are to be supported. If
        there are at least 32 rows in the table and a new Measurement Interval
        completes and a new row is to be added to the table, the oldest completed
        Measurement Interval is deleted (row deletion).

        The rows and objects in this table are to be persistent upon reboot
        or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
        for tnEthSoamPmSessionCfgType of 'ece'
       "
    ::= { tnEthSoamPmEceStatsObjects 1 }

tnEthSoamPmEceHistoryStatsEntry OBJECT-TYPE
    SYNTAX      TnEthSoamPmEceHistoryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "The conceptual row of tnEthSoamPmEceHistoryStatsTable"
    INDEX      { tnEthSoamPmEceHistoryStatsIndex, tnEvcEceId, ifIndex }
    ::= { tnEthSoamPmEceHistoryStatsTable 1 }

TnEthSoamPmEceHistoryStatsEntry ::= SEQUENCE {
    tnEthSoamPmEceHistoryStatsIndex                  Unsigned32,
    tnEthSoamPmEceHistoryStatsEndTime                DateAndTime,
    tnEthSoamPmEceHistoryStatsElapsedTime            TimeInterval,
    tnEthSoamPmEceHistoryStatsGreenFramesTx          Counter64,
    tnEthSoamPmEceHistoryStatsGreenFramesRx          Counter64,
    tnEthSoamPmEceHistoryStatsGreenBytesTx           Counter64,
    tnEthSoamPmEceHistoryStatsGreenBytesRx           Counter64,
    tnEthSoamPmEceHistoryStatsYellowFramesTx         Counter64,
    tnEthSoamPmEceHistoryStatsYellowFramesRx         Counter64,
    tnEthSoamPmEceHistoryStatsYellowBytesTx          Counter64,
    tnEthSoamPmEceHistoryStatsYellowBytesRx          Counter64,
    tnEthSoamPmEceHistoryStatsRedFramesRx            Counter64,
    tnEthSoamPmEceHistoryStatsRedBytesRx             Counter64,
    tnEthSoamPmEceHistoryStatsDiscardFramesTx        Counter64,
    tnEthSoamPmEceHistoryStatsDiscardFramesRx        Counter64,
    tnEthSoamPmEceHistoryStatsDiscardBytesTx         Counter64,
    tnEthSoamPmEceHistoryStatsDiscardBytesRx         Counter64
}

tnEthSoamPmEceHistoryStatsIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "The index for the Measurement Interval within this PM session.

        Measurement Interval indexes are assigned sequentially by
        the device.  The first Measurement Interval that occurs after
        the session is started is assigned index 1.

        Referential integrity is necessary, i.e., the index needs to be
        persistent upon a reboot or restart of a device.  The index
        is never reused while this session is active until it wraps to zero.
        The index value keeps increasing up to that time.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 1 }

tnEthSoamPmEceHistoryStatsEndTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval ended.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 2 }

tnEthSoamPmEceHistoryStatsElapsedTime OBJECT-TYPE
    SYNTAX      TimeInterval
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The time that this Measurement Interval has been running, in 0.01
        seconds.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 3 }

tnEthSoamPmEceHistoryStatsGreenFramesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound frames within 
        the CIR / CBS compliance level in this ECE for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 4 }

tnEthSoamPmEceHistoryStatsGreenFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames
        within the CIR / CBS compliance level in this
        ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 5 }

tnEthSoamPmEceHistoryStatsGreenBytesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound bytes, where
        frames are within the CIR / CBS compliance level in this
        ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 6 }

tnEthSoamPmEceHistoryStatsGreenBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes, where
        frames are within the CIR / CBS compliance level in this
        ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 7 }

tnEthSoamPmEceHistoryStatsYellowFramesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound frames
        exceeding the CIR/CBS but within the EIR/EBS
        in this ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 8 }

tnEthSoamPmEceHistoryStatsYellowFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames
        exceeding the CIR/CBS but within the EIR/EBS
        in this ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 9 }

tnEthSoamPmEceHistoryStatsYellowBytesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound bytes, where
        frames exceed the CIR/CBS but are within the EIR/EBS
        in this ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 10 }

tnEthSoamPmEceHistoryStatsYellowBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes, where
        frames exceed the CIR/CBS but are within the EIR/EBS
        in this ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 11 }

tnEthSoamPmEceHistoryStatsRedFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames
        not conforming to either the CIR/CBS or the EIR/EBS
        in this ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 12 }

tnEthSoamPmEceHistoryStatsRedBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes, where
        frames do not conform to either the CIR/CBS or the EIR/EBS
        in this ECE for this Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 13 }

tnEthSoamPmEceHistoryStatsDiscardFramesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound frames which
        were chosen to be discarded in this ECE for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 14 }

tnEthSoamPmEceHistoryStatsDiscardFramesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound frames which
        were chosen to be discarded in this ECE for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 15 }

tnEthSoamPmEceHistoryStatsDiscardBytesTx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of outbound bytes which
        were chosen to be discarded in this ECE for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 16 }

tnEthSoamPmEceHistoryStatsDiscardBytesRx OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This object contains the number of inbound bytes which
        were chosen to be discarded in this ECE for this
        Measurement Interval.
       "
    ::= { tnEthSoamPmEceHistoryStatsEntry 17 }


-- ******************************************************************
-- TN Ethernet Port History Statistic Table
-- ******************************************************************
-- tnEthSoamPmPortHistoryStatsTable OBJECT-TYPE
--     SYNTAX      SEQUENCE OF TnEthSoamPmPortHistoryStatsEntry
--     MAX-ACCESS  not-accessible
--     STATUS      current
--     DESCRIPTION
--        "This table contains the results for history Measurement
--         Intervals in a SOAM Port Measurement session.
-- 
--         Rows of this table object are created automatically by the
--         SNMP Agent when the Port Measurement session is running and a
--         Measurement Interval is completed.
-- 
--         Each row in the table represents the history statistics for a Port
--         Measurement session availability Measurement Interval for the defined
--         port.
-- 
--         32 completed Measurement Intervals are to be supported. If
--         there are at least 32 rows in the table and a new Measurement Interval
--         completes and a new row is to be added to the table, the oldest completed
--         Measurement Interval is deleted (row deletion).
-- 
--         The rows and objects in this table are to be persistent upon reboot
--         or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
--         for tnEthSoamPmSessionCfgType of 'port'.
--        "
--     ::= { tnEthSoamPmPortStatsObjects 1 }
-- 
-- tnEthSoamPmPortHistoryStatsEntry OBJECT-TYPE
--     SYNTAX      TnEthSoamPmPortHistoryStatsEntry
--     MAX-ACCESS  not-accessible
--     STATUS      current
--     DESCRIPTION
--             "The conceptual row of tnEthSoamPmPortHistoryStatsTable"
--     INDEX      { tnEthSoamPmPortHistoryStatsIndex, ifIndex }
--     ::= { tnEthSoamPmPortHistoryStatsTable 1 }
-- 
-- TnEthSoamPmPortHistoryStatsEntry ::= SEQUENCE {
--     tnEthSoamPmPortHistoryStatsIndex                  Unsigned32,
--     tnEthSoamPmPortHistoryStatsEndTime                DateAndTime,
--     tnEthSoamPmPortHistoryStatsElapsedTime            TimeInterval,
--     tnEthSoamPmPortHistoryStatsTxOctets               Counter64,
--     tnEthSoamPmPortHistoryStatsRxOctets               Counter64,
--     tnEthSoamPmPortHistoryStatsTxPkts                 Counter64,
--     tnEthSoamPmPortHistoryStatsRxPkts                 Counter64,
--     tnEthSoamPmPortHistoryStatsTxBroadcastPkts        Counter64,
--     tnEthSoamPmPortHistoryStatsRxBroadcastPkts        Counter64,
--     tnEthSoamPmPortHistoryStatsTxMulticastPkts        Counter64,
--     tnEthSoamPmPortHistoryStatsRxMulticastPkts        Counter64
-- }
-- 
-- tnEthSoamPmPortHistoryStatsIndex OBJECT-TYPE
--     SYNTAX      Unsigned32 (1..4294967295)
--     MAX-ACCESS  not-accessible
--     STATUS      current
--     DESCRIPTION
--        "The index for the Measurement Interval within this PM session.
-- 
--         Measurement Interval indexes are assigned sequentially by
--         the device.  The first Measurement Interval that occurs after
--         the session is started is assigned index 1.
-- 
--         Referential integrity is necessary, i.e., the index needs to be
--         persistent upon a reboot or restart of a device.  The index
--         is never reused while this session is active until it wraps to zero.
--         The index value keeps increasing up to that time.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 1 }
-- 
-- tnEthSoamPmPortHistoryStatsEndTime OBJECT-TYPE
--     SYNTAX      DateAndTime
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The time that this Measurement Interval ended.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 2 }
-- 
-- tnEthSoamPmPortHistoryStatsElapsedTime OBJECT-TYPE
--     SYNTAX      TimeInterval
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The time that this Measurement Interval has been running, in 0.01
--         seconds.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 3 }
-- 
-- tnEthSoamPmPortHistoryStatsTxOctets OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The total number of octets transmitted out of the interface
--         for this Measurement Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 4 }
-- 
-- tnEthSoamPmPortHistoryStatsRxOctets OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The total number of octets received on the interface
--         for this Measurement Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 5 }
-- 
-- tnEthSoamPmPortHistoryStatsTxPkts OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The total number of packets transmitted out of the interface
--         for this Measurement Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 6 }
-- 
-- tnEthSoamPmPortHistoryStatsRxPkts OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The total number of packets received on the interface
--         for this Measurement Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 7 }
-- 
-- tnEthSoamPmPortHistoryStatsTxBroadcastPkts OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The total number of packets that higher-level protocols
--         requested be transmitted, and which were addressed to a
--         broadcast address at this sub-layer for this Measurement
--         Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 8 }
-- 
-- tnEthSoamPmPortHistoryStatsRxBroadcastPkts OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The number of packets, delivered by this sub-layer to a
--         higher (sub-)layer, which were addressed to a broadcast
--         address at this sub-layer for this Measurement Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 9 }
-- 
-- tnEthSoamPmPortHistoryStatsTxMulticastPkts OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The total number of packets that higher-level protocols
--         requested be transmitted, and which were addressed to a
--         multicast address at this sub-layer for this Measurement
--         Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 10 }
-- 
-- tnEthSoamPmPortHistoryStatsRxMulticastPkts OBJECT-TYPE
--     SYNTAX      Counter64
--     MAX-ACCESS  read-only
--     STATUS      current
--     DESCRIPTION
--        "The number of packets, delivered by this sub-layer to a
--         higher (sub-)layer, which were addressed to a multicast
--         address at this sub-layer for this Measurement Interval.
--        "
--     ::= { tnEthSoamPmPortHistoryStatsEntry 11 }

END